How to create an inexpensive flow through connector for installing Channel Systems.
(works best on PVC pipe installations—similar I.D.)
- Cut a 6 inch length of pipe.
- Cut out a longitudinal segment to correspond to the table below.
- Compress the cut pipe to fit inside the host pipe.
- Slip on RELINER® pipe end and install RELINER®.
- Cover the split pipe gap with duct tape.
- Remove split pipe when concrete has set.

| Pipe Diameter (SDR 35) | For Good Alignment Remove | For up to 10 degrees Misalignment Remove |
| 6" | 1 1/4" | 1 1/2" |
| 8" | 1 3/4" | 2" |
| 10" | 2" | 2 1/2" |
| 12" | 2 1/2" | 3" |
| 15" | 3" | 3 3/4" |
| 18" | 3 1/2" | 4 1/2" |
|
|