CHANNEL SYSTEM INSTALLATION




Clear flume path


Cut pipe ends to fit


Bolt together


Backfill with concrete


CHANNEL SYSTEM INSTALLATION INSTRUCTIONS

  1. Remove the existing brick and mortar invert in the flume path.
  2. Lay out and align the flume parts.
  3. Trim pipe extensions to fit the existing pipes.
  4. Drill 4 holes in each flange for the 1/4" stainless steel bolts (supplied).
  5. Bolt RELINER parts together.
  6. Locate a long style inflatable line plug in each line (inlets and outlets) so that the plug is 1/2 in host pipe and 1/2 in RELINER pipe. (Use by-pass plugs for high flow conditions). OR Locate channels using split pipe technique (see Tech Tip)
  7. Inflate line plugs and brace entire assembly to prevent flotation.
  8. Backfill with concrete.
  9. When concrete cures, remove plugs.
For technical support, call 800-508-6001

EQUIPMENT SUGGESTED FOR CHANNEL SYSTEM INSTALLATION

  • Cut off saw, 4 1/2" angle grinder or air-powered muffler cut off tool
  • Drill with bits (9/32 recommended)
  • Vise grips (2 mininum)
  • Tape measure
  • Line plugs same diameters as in structures OR see Tech Tip
  • Length of PVC pipe (2-3 feet) same diameters as in structures
  • Duct tape
  • Hydraulic cement (quick setting)
  • Wrenches 7/16
  • Magic Marker (permanent)
  • Concrete mix - approx 1/2 yard
  • 5 gallon pails
  • Steel trowels
  • Jack-hammer 90#
  • Mason's hammer
  • Chisel
  • Rope
  • Shovel